| Part | Title | Purpose | |------|-------|---------| | | General tolerances for linear and angular dimensions | Defines tolerance classes (f, m, c, v) for sizes, radii, chamfers, and angles | | ISO 2768-2 | General tolerances for geometrical features | Defines tolerance classes (H, K, L) for straightness, flatness, parallelism, perpendicularity, symmetry, runout |
GENERAL TOLERANCES: ISO 2768-MK-E Alternatively: iso 2768-mk-e
– Same values as perpendicularity. Circular runout – 0.2 mm (class K). Total runout – Not defined; must be specified individually. Example: A 200 mm long machined surface without a flatness callout → allowed flatness deviation = 0.3 mm. 3.3 "E" – External Radii & Chamfer Heights (ISO 2768-1 Annex A) The "E" instructs that tolerances for external radii and chamfer heights follow the same "M" class limits as linear dimensions, but applied to the radius or chamfer size. | Part | Title | Purpose | |------|-------|---------|